Binocular Fluorescence Microscope

Binocular Fluorescence Microscope
Binocular Fluorescence Microscope

Binocular Fluorescence Microscope Specification

  • View Head
  • Binocular, 45 inclined, 360 rotatable
  • Focus System
  • Coaxial coarse and fine focusing system
  • Features
  • High quality optics; Anti-fungus coatings; Sturdy metal frame; Suitable for fluorescence observation; Ergonomic design; Long working distance optics; Wide field of view
  • Spare Parts
  • Spare lamp, fuse, immersion oil, dust cover, users manual
  • Theory
  • Fluorescence microscopy utilizes high-intensity illumination to excite fluorescent substances in the specimen, which then emit detectable light for imaging detailed cellular structures.
  • Drawtube
  • Binocular
  • Sensor
  • Not specified (camera dependent)
  • Resolution
  • High-resolution optical system (exact value Not specified)
  • Interface
  • Not specified (depends on camera or imaging system used)
  • Frame Rate
  • Not specified (camera dependent)
  • Focal Distance
  • Not specified (Dependent on objective used)
  • Magnification
  • 40X-1000X (using objective lenses 4X, 10X, 40X, 100X with 10X eyepieces)
  • Dimensions
  • Approx. 470 x 360 x 220 mm (may vary with models)
  • Focus Range
  • Coarse and Fine Adjustment
  • Eyepieces
  • Wide-field 10X (paired)
  • Eyepiece Tube
  • 45-degree inclined, 360-degree rotatable
  • Illumination
  • LED or Mercury/High-Pressure Sodium Lamp, suitable for fluorescence applications
  • Coarse Adjustment Range
  • Approx. 30mm
  • Fine Adjustment Range
  • Approx. 0.002mm
  • Working Stage
  • Double layer mechanical stage, size approx. 140140 mm, travel range 7550 mm
  • Still Image Capture Resolution
  • Not specified (camera dependent)
  • Video Capture Resolution
  • Not specified (camera dependent)
  • Image Format
  • Not specified (compatible with microscope camera)
  • Interpupillary Distance
  • Adjustable, 55 - 75 mm
  • Objective Achromatic
  • 4X, 10X, 40X (spring), 100X (spring, oil, fluorescence)
  • Condenser
  • Abbe condenser, N.A. 1.25, with iris diaphragm
  • Light Source
  • LED/High pressure lamp, with adjustable intensity
  • Filter Set
  • Integrated excitation and emission filter sets for fluorescence applications
  • Dust Protection
  • Supplied with fitted dust cover
  • Body Material
  • Heavy-duty metal body with anti-rust coatings
  • Nosepiece
  • Quadruple revolving nosepiece
  • Diopter Adjustment
  • Provided on both eyepieces
  • Weight
  • Approx. 8-10 kg (without accessories)
  • Power Supply
  • AC 220V/110V, 50/60Hz adaptable
  • Application
  • Cell biology, microbiology, pathology, medical diagnostics, teaching, research
  • Stage Movement
  • X-Y mechanical control with smooth movements
  • Safety Features
  • Overcurrent protection, thermal cut-off for lamp
 
 

About Binocular Fluorescence Microscope

A Robust and stable die-caststable body with Co-Axial coarse and fine focusing  mechanism based on four step reeducation gearssystem which runs on ball- bearing guide ways with tension control ring.Stopper system is provided so that the slides may not damage.

Binocular Head Inclined at 45/30deg.With all Anti-Fungal Coating prisms. Ratable 360 deg. IPD adjustment between 54mm -74mm.

Nose Piece A high precision quadruple nose piece running on Balls with positive indexing.

All positions are parcentered and personalized

Mechanical Stage- Lowpositioned Co-axial calibrated double plate mechanical with feather touchmovement. Wide Field eye piece.

Epi Fluorescent System: The Epi-Illuminationis through 100W Ultra High pressure Mercury Lamp in a Lamp House attached to the Fluorescence Filter Block.

Filters -Two Exciting filters B (Blue), G (Green) Exciting light Filter system, O Ordinary Light System.

Protection Barrier- Orangecoloured plastic screen protection barrier to resist the Ultra Violet Light.

Eye Piece- High Eye PointAnti Fungal Extra Wide Field 10x /FN 18mm) paired eye piece

FluorescenceObjective: 4x,10x,40x(SL) ,100xOil(SL) with Immersion Oil  Fluorescence Free  Power : AC input 220V,Indicator Display.                                                                                 



Engineered for Precision and Durability

Constructed from a heavy-duty metal frame with anti-rust coatings, this microscope promises long-term stability and minimal maintenance. The double-layer mechanical stage, smooth X-Y control, and ergonomic design ensure effortless operation and comfort during extended use.


Advanced Fluorescence Imaging Capability

Integrated excitation and emission filter sets make this microscope perfect for discerning cellular structures using fluorescence techniques. The high-quality optics, wide field of view, and adjustable illumination allow for bright, clear, and detailed visualization, essential for advanced biological and diagnostic applications.


Safety, Ease, and Versatility in One

With adaptive AC power supply, overcurrent and thermal cut-off protection, and user-centric features like coaxial focus adjustments, this microscope is safe and convenient for diverse environments. Its robust construction, supplied dust cover, and spare parts package enhance reliability and longevity.

FAQ's of Binocular Fluorescence Microscope:


Q: How does the microscope achieve fluorescence imaging?

A: The microscope utilizes high-intensity LED or mercury/pressure sodium lamps to excite fluorescent substances in specimens. Specialized integrated excitation and emission filter sets allow only the desired wavelength to reach the viewer, resulting in vivid fluorescent images of cellular structures.

Q: What is the process for adjusting focus and stage movement?

A: The microscope features a coaxial coarse and fine focusing system for precise focus adjustment, with coarse and fine ranges of approximately 30mm and 0.002mm, respectively. The double-layer mechanical stage is moved smoothly using X-Y mechanical controls, ensuring accurate specimen positioning.

Q: Where is this microscope applicable and what are its main uses?

A: It is widely used in cell biology, microbiology, pathology, medical diagnostics, teaching, and general research where fluorescence imaging is necessary. Its versatility and high-resolution optics make it suitable for a variety of laboratory-based applications.

Q: What benefits does the anti-rust heavy-duty metal body provide?

A: The robust metal frame with anti-rust coatings delivers enhanced durability and resistance to environmental damage, ensuring stable, long-term operation and reduced maintenance costs-ideal for frequent use in laboratories or teaching environments.

Q: When should overcurrent and thermal safety features be considered?

A: These features are particularly important when operating for extended periods or using high-intensity illumination. Overcurrent protection and thermal cut-off for the lamp prevent electrical or thermal overload, protecting both the microscope and the user.

Q: How is dust protected when the microscope is not in use?

A: A fitted dust cover is supplied with the microscope, effectively safeguarding optical and mechanical components from dust accumulation and preserving image clarity and equipment longevity.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Laboratory Microscope Category

Trinocular Inverted Microscope

Trinocular Inverted Microscope

View Head : Trinocular head, 360 rotatable.

Illumination : LED (6V/20W halogen or LED with adjustable brightness).

Working Stage : Mechanical stage with XY movement, size 230 x 150 mm.

Eyepieces : Wide field 10X/18mm, eyeguard included.

Theory : Other, Trinocular Inverted Microscope designed for observing living cells, tissues, and other samples in culture medium.

Magnification : Total magnification 40X to 400X (objectives 4X, 10X, 20X, 40X LWD plus 10X wide field eyepiece).

Stereo Binocular Microscope

Stereo Binocular Microscope

View Head : Binocular, 360 rotatable

Illumination : Incident (top) and transmitted (bottom) LED or halogen light

Working Stage : Frosted glass stage with stage clips

Eyepieces : Widefield 10x paired (Adjustable diopter)

Theory : Other, Stereo vision microscopy for 3D viewing of specimens

Magnification : 20x and 40x (Typically with 2x objective and 10x eyepieces)

Student Dissecting Microscopes

Student Dissecting Microscopes

View Head : 360 rotatable monocular head

Illumination : Planoconcave mirror, natural/ambient light

Working Stage : Glass stage plate, 75 mm diameter with fixed clips

Eyepieces : 10x paired widefield lens

Theory : Other, Upright, single body design for student use

Magnification : 10x and 20x standard

Student Polarizing Microscope

Student Polarizing Microscope

View Head : Monocular Head

Illumination : Builtin LED or halogen light source

Working Stage : Mechanical Stage with XY adjustment

Eyepieces : 10x & 15x

Theory : Other, Light polarization microscopy theory

Magnification : 40x to 1000x



Back to top