Ambala, Haryana, India

call images

Call us

08045479243

Photo Colorimeter

Photo Colorimeter
Photo Colorimeter

Photo Colorimeter Specification

  • Accuracy
  • 0.5% FSD
  • Response Time
  • < 2 seconds
  • Measuring Range
  • 400 to 700 nm (wavelength)
  • Application
  • Chemical and clinical analysis, laboratory use
  • Specimen Size
  • Cuvette 10 mm path length
  • Operating Voltage
  • 220V AC, 50 Hz
  • Temperature
  • 10C to 40C
  • Mounting Type
  • Tabletop
  • Resolution
  • 0.01 O.D.
  • Number of Specimens
  • Single cuvette
  • Frequency
  • 50 Hz
  • Power Supply
  • 220V AC, 50Hz
  • Equipment Type
  • Photo Colorimeter
  • Test Range
  • 0100% T & 01.99 O.D.
  • Humidity
  • Up to 80% RH (Non-condensing)
  • Automation Grade
  • Semi-automatic
  • Interface Type
  • Analog
  • Display Type
  • LED digital display
  • Features
  • Portable, user-friendly, accurate readings, robust design
  • Usage
  • Laboratory analysis of solutions
  • Machine Weight
  • 2.5 kg (approx)
  • Control Mode
  • Manual / Digital
  • Light Source
  • Tungsten lamp
  • Wavelength Selection
  • Manual, filter wheel
  • Filters
  • Standard glass filters (8 position, selectable)
  • Transmittance Range
  • 0-100% T
  • Calibration
  • Manual/automatic zero adjustment
  • Detector
  • Photocell/Silicon photodiode
  • Cuvette Holder Material
  • Corrosion resistant
  • Optical Density Range
  • 0-1.99 O.D.
  • Sample Volume
  • 15 ml
 

Photo Colorimeter Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 10 Pieces Per Day
  • Delivery Time
  • 1 Week
 

About Photo Colorimeter

Photo Colorimeter

  • DIGITAL PHOTO COLORIMETER 8 filters Mains operated, sample size 1 ml with 2 digit LED display..
  • DIGITAL PHOTO COLORIMETER 5 filters Mains operated, sample size 1 ml with 2 digit LED display.
  • FILTER PHOTO COLORIMETER 8 filters Mains operated, sample size I ml with 100x125 meter scale in % Transmission and Absorbance.
  • FILTER PHOTO COLORIMETER 5 filters Mains operated, sample size 1ml with 100x125mm meter scale in % T and Absorbance.

 

OPTIONAL:

  • Standard Glass Filter, Each colour.
  • Test tube set of 5 for colorimeter.
  • Photocell/photo diode.
  • Set of 2 Glass cuvettes (10mm path length)
  • Spare lamp 6V 300mA

 



Accurate and Versatile Laboratory Analysis

Built for a variety of chemical and clinical applications, this colorimeter provides accurate transmittance and optical density readings. With a selectable filter wheel and high-precision detectors, users can confidently analyze solutions across a broad wavelength range. Its robust and corrosion-resistant build ensures durability for daily laboratory use.


User-Centric Operation and Easy Calibration

The machine offers both manual and digital controls, supporting straightforward operation. Manual or automatic zero adjustments facilitate quick calibration. Its responsive interface, featuring an LED digital display, delivers results in under two seconds, making routine lab work efficient and reliable.

FAQs of Photo Colorimeter:


Q: How do I select the desired wavelength using this photo colorimeter?

A: The colorimeter features a manual, 8-position filter wheel equipped with standard glass filters. You simply rotate the wheel to select the appropriate filter corresponding to your required wavelength within the 400 to 700 nm range.

Q: What benefits does the corrosion-resistant cuvette holder provide?

A: The corrosion-resistant cuvette holder ensures long-term durability and prevents chemical degradation, making the instrument reliable for repeated use in environments where caustic or reactive samples are handled.

Q: When is it necessary to perform calibration on this photo colorimeter?

A: Calibration should be performed before each use or whenever you change samples to ensure accurate readings. The equipment supports both manual and automatic zero adjustment for flexible calibration options.

Q: Where can this photo colorimeter be most effectively used?

A: This instrument is ideal for laboratory environments engaging in chemical and clinical analysis, making it suitable for research labs, educational institutes, and healthcare facilities.

Q: What is the process for measuring optical density or transmittance with this device?

A: First, select the appropriate filter for your analysis. Insert the cuvette with your sample into the corrosion-resistant holder, adjust to zero using a blank sample, and then measure the transmittance or optical density. The LED digital display provides accurate results within seconds.

Q: How does the digital control enhance the instruments usability?

A: Digital control simplifies operations and offers enhanced accuracy. The LED digital display clearly shows readings, ensuring user-friendly data interpretation and streamlined analysis workflows.

Price 4000 INR/ Piece

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 10 Pieces Per Day
  • Delivery Time
  • 1 Week
Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Analytical Instruments Category

Semi Auto Chemistry Analyzer

Semi Auto Chemistry Analyzer

Application : Clinical biochemistry tests in laboratories

Power Supply : AC 220V 10%, 50Hz

Test Range : 0 3.0 Abs

Humidity : 10% 90% (noncondensing)

Usage : Hospital & diagnostic laboratories

Automation Grade : Semi Automatic

Auto Karl Fischer Titrimeter

Auto Karl Fischer Titrimeter

Application : Determination of water content in solids/liquids

Power Supply : 230V AC 10%, 50 Hz

Test Range : 10 ppm to 100% water content

Humidity : Up to 80% RH (noncondensing)

Usage : Laboratory Moisture analysis

Automation Grade : Automatic

Digital Turbidity Thermometer

Digital Turbidity Thermometer

Application : Water quality testing, laboratory analysis

Power Supply : AC 220V, 50Hz

Test Range : 0 to 2000 NTU

Humidity : Up to 80% RH

Usage : Turbidity & temperature measurement

Automation Grade : Automatic

Dissolved Oxygenmeter

Dissolved Oxygenmeter

Application : Measuring dissolved oxygen in water

Power Supply : 2 x 1.5 V AA Batteries

Test Range : 0 20.0 mg/L (DO)

Humidity : <85% RH

Usage : Field/Laboratory Water Test

Automation Grade : SemiAutomatic



Back to top